MagPlex® Microspheres
Magnetic microspheres offer improved washing efficiency and the ability to measure up to 500 targets simultaneously
About
Similar to MicroPlex® Microspheres, MagPlex® Microspheres are carboxylated polystyrene microparticles, or “beads,” that have been dyed into spectrally distinct sets, or “regions,” allowing them to be individually identified by an xMAP® instrument. These uniquely color-coded beads provide a user with an addressable substrate on which to perform multiple bio-analytical reactions in a single well.
There are several advantages to MagPlex® Microspheres over traditional MicroPlex® Microspheres. MagPlex® Microspheres are magnetic, and with the use of a magnetic separator, they can be separated from solution quickly and easily. This improves bead recovery during handling and wash steps and facilitates assay automation.
Additionally, MagPlex® Microspheres are available in 500 unique regions, enabling the development of assays that can measure up to 500 different analytes in the same well.
These beads are universally compatible with all xMAP® instruments. MagPlex® Microspheres open the door to Luminex’s MAGPIX® instrument, which was designed as a simple and easy-to-use instrument with a smaller footprint.
All microspheres are general-use components for further manufacture of xMAP® bioassays.
MagPlex® Microspheres are available at a concentration of 2.5 million and 12.5 million beads/mL and can be ordered in 1 mL and 4 mL vial sizes. MagPlex® Microspheres are also offered in a variety of custom volumes. Please see the MagPlex® Custom Volume Ordering Guidelines or contact Luminex to inquire about custom volume options.
Features
- Surface carboxyl groups
- Superparamagnetic
- 500 Regions available
- Compatible with all xMAP® Instruments
- Multiple vial sizes available
- Multiple concentrations available
Benefits
- Same reliable coupling chemistry as MicroPlex
- 5X Increased multiplex capability
- Improved washing efficiency
- Ideal for automated applications
- No need for expensive filter plates
- Available in low concentration, for small scale and assay development applications
To be used on
Instruments designed to accelerate reliable results while simplifying complexity.
xMAP INTELLIFLEX® System
The only compact, flow-based, multiplex platform that combines the proven xMAP technology with modern features to enhance performance, empower innovation, and simplify your user experience.
Luminex® 200™ System
A fast, cost-effective, flow-based analyzer that simultaneously measures up to 100 analytes in a single microplate well.
MAGPIX® System
A compact, fast, cost-effective, imaging-based analyzer that simultaneously measures up to 50 analytes in a single microplate well.
Ordering info
All MagPlex® Microsphere orders, 1 and 4 mL volumes, ship within three business days of order receipt. However, backordered items may have longer than normal lead times. MagPlex® Microspheres have a maximum shelf life of five years from the date of manufacture and all MagPlex® Microspheres are guaranteed to have a minimum remaining shelf life from the date they ship. Group A and B regions have a minimum shelf life of six months from the date of shipment and Group C regions have a minimum shelf life of three months from the ship date. Please see product part numbers below before placing your order to see which regions are compatible with your instrument. Please refer to our Reagent Shipping Policy for more information.
Group A (50)
|
Group B (30)
|
Group C (420)
|
|||
---|---|---|---|---|---|
Reg. | Part number | Reg. | Part number | Reg. | Part number |
12 | MC10012-YY | 7 | MC10007-YY | 1 | MC12001-01 |
13 | MC10013-YY | 8 | MC10008-YY | 2 | MC12002-01 |
14 | MC10014-YY | 9 | MC10009-YY | 3 | MC12003-01 |
15 | MC10015-YY | 49 | MC10049-YY | 4 | MC12004-01 |
18 | MC10018-YY | 58 | MC10058-YY | 5 | MC12005-01 |
19 | MC10019-YY | 59 | MC10059-YY | 6 | MC12006-01 |
20 | MC10020-YY | 68 | MC10068-YY | 10 | MC12010-01 |
21 | MC10020-YY | 69 | MC10069-YY | 11 | MC12011-01 |
22 | MC10022-YY | 70 | MC10070-YY | 16 | MC12016-01 |
25 | MC10025-YY | 79 | MC10079-YY | 17 | MC12017-01 |
26 | MC10026-YY | 80 | MC10080-YY | 23 | MC12023-01 |
27 | MC10027-YY | 81 | MC10081-YY | 24 | MC12024-01 |
28 | MC10028-YY | 82 | MC10082-YY | 31 | MC12031-01 |
29 | MC10029-YY | 83 | MC10083-YY | 32 | MC12032-01 |
30 | MC10030-YY | 84 | MC10084-YY | 40 | MC12041-01 |
33 | MC10033-YY | 85 | MC10085-YY | 41 | MC12041-01 |
34 | MC10034-YY | 86 | MC10086-YY | 50 | MC12050-01 |
35 | MC10035-YY | 87 | MC10087-YY | 60 | MC12060-01 |
36 | MC10036-YY | 88 | MC10088-YY | 71 | MC12071-01 |
37 | MC10037-YY | 89 | MC10089-YY | 92 | MC12092-01 |
38 | MC10038-YY | 90 | MC10090-YY | 101+ | MC10XXX-01 |
39 | MC10039-YY | 91 | MC10091-YY | ||
42 | MC10042-YY | 93 | MC10093-YY | ||
43 | MC10043-YY | 94 | MC10094-YY | ||
44 | MC10044-YY | 95 | MC10095-YY | ||
45 | MC10045-YY | 96 | MC10096-YY | ||
46 | MC10046-YY | 97 | MC10097-YY | ||
47 | MC10047-YY | 98 | MC10098-YY | ||
48 | MC10048-YY | 99 | MC10099-YY | ||
51 | MC10051-YY | 100 | MC10100-YY | ||
52 | MC10052-YY | ||||
53 | MC10053-YY | ||||
54 | MC10054-YY | ||||
55 | MC10055-YY | ||||
56 | MC10056-YY | ||||
57 | MC10057-YY | ||||
61 | MC10061-YY | ||||
62 | MC10062-YY | ||||
63 | MC10063-YY | ||||
64 | MC10064-YY | ||||
65 | MC10065-YY | ||||
66 | MC10066-YY | ||||
67 | MC10067-YY | ||||
72 | MC10072-YY | ||||
73 | MC10073-YY | ||||
74 | MC10074-YY | ||||
75 | MC10075-YY | ||||
76 | MC10076-YY | ||||
77 | MC10077-YY | ||||
78 | MC10078-YY |
[-YY] = [-01] for 1 mL;
[-04] for 4 mL; or
[-ID] for 1 mL Low Concentration
Please contact Luminex to inquire about custom vial sizes.
Region |
Region group |
Instrument compatibility |
Part number |
---|---|---|---|
1 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12001-01 |
2 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12002-01 |
3 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12003-01 |
4 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12004-01 |
5 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12005-01 |
6 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12006-01 |
7 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10007-YY |
8 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10008-YY |
9 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10009-YY |
10 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12010-01 |
11 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12011-01 |
12 | Group A | All xMAP® Instruments* | MC10012-YY |
13 | Group A | All xMAP® Instruments* | MC10013-YY |
14 | Group A | All xMAP® Instruments* | MC10014-YY |
15 | Group A | All xMAP® Instruments* | MC10015-YY |
16 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12016-01 |
17 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12017-01 |
18 | Group A | All xMAP® Instruments* | MC10018-YY |
19 | Group A | All xMAP® Instruments* | MC10019-YY |
19 | Group A | All xMAP® Instruments* | MC10019-YY |
19 | Group A | All xMAP® Instruments* | MC10019-YY |
20 | Group A | All xMAP® Instruments* | MC10020-YY |
21 | Group A | All xMAP® Instruments* | MC10021-YY |
22 | Group A | All xMAP® Instruments* | MC10022-YY |
23 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12023-01 |
24 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12024-01 |
25 | Group A | All xMAP® Instruments* | MC10025-YY |
26 | Group A | All xMAP® Instruments | MC10026-YY |
27 | Group A | All xMAP® Instruments | MC10027-YY |
28 | Group A | All xMAP® Instruments | MC10028-YY |
29 | Group A | All xMAP® Instruments | MC10029-YY |
30 | Group A | All xMAP® Instruments | MC10030-YY |
31 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12031-01 |
32 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12032-01 |
33 | Group A | All xMAP® Instruments | MC10033-YY |
34 | Group A | All xMAP® Instruments | MC10034-YY |
35 | Group A | All xMAP® Instruments | MC10035-YY |
36 | Group A | All xMAP® Instruments | MC10036-YY |
37 | Group A | All xMAP® Instruments | MC10037-YY |
38 | Group A | All xMAP® Instruments | MC10038-YY |
39 | Group A | All xMAP® Instruments | MC10039-YY |
40 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12040-01 |
41 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12041-01 |
42 | Group A | All xMAP® Instruments | MC10042-YY |
43 | Group A | All xMAP® Instruments | MC10043-YY |
44 | Group A | All xMAP® Instruments | MC10044-YY |
45 | Group A | All xMAP® Instruments | MC10045-YY |
46 | Group A | All xMAP® Instruments | MC10046-YY |
47 | Group A | All xMAP® Instruments | MC10047-YY |
48 | Group A | All xMAP® Instruments | MC10048-YY |
49 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10049-YY |
50 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12050-01 |
51 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10051-YY |
52 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10052-YY |
53 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10053-YY |
54 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10054-YY |
55 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10055-YY |
56 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10056-YY |
57 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10057-YY |
58 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10058-YY |
59 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10059-YY |
60 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12060-01 |
61 | Group A | All xMAP® Instruments | MC10061-YY |
62 | Group A | All xMAP® Instruments | MC10062-YY |
63 | Group A | All xMAP® Instruments | MC10063-YY |
64 | Group A | All xMAP® Instruments | MC10064-YY |
65 | Group A | All xMAP® Instruments | MC10065-YY |
66 | Group A | All xMAP® Instruments | MC10066-YY |
67 | Group A | All xMAP® Instruments | MC10067-YY |
68 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10068-YY |
69 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10069-YY |
70 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10070-YY |
71 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12071-01 |
72 | Group A | All xMAP® Instruments | MC10072-YY |
73 | Group A | All xMAP® Instruments | MC10073-YY |
74 | Group A | All xMAP® Instruments | MC10074-YY |
75 | Group A | All xMAP® Instruments | MC10075-YY |
76 | Group A | All xMAP® Instruments | MC10076-YY |
77 | Group A | All xMAP® Instruments | MC10077-YY |
78 | Group A | All xMAP® Instruments | MC10078-YY |
79 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10079-YY |
80 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10080-YY |
81 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10081-YY |
82 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10082-YY |
83 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10083-YY |
84 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10084-YY |
85 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10085-YY |
86 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10086-YY |
87 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10087-YY |
88 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10088-YY |
89 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10089-YY |
90 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10090-YY |
91 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10091-YY |
92 | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC12092-01 |
93 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10093-YY |
94 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10094-YY |
95 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10095-YY |
96 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10096-YY |
97 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10097-YY |
98 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10098-YY |
99 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10099-YY |
100 | Group B | Luminex® 200™, FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10100-YY |
101+ | Group C | FLEXMAP 3D® and xMAP INTELLIFLEX® | MC10XXX-01 |
Resources
Blog
Discover morexMAP Insights magazine
Discover morexMAP Resource Round-Up
Discover moreResearch publications
Discover moreDocument repository
Product documentationWhite papers
Discover morexMAP® Kit Finder
Discover morePartners
Discover moreFind out more about all the xMAP® Microspheres
Delivering the versatility to perform a wide range of protein and nucleic acid-based multiplex assays—on a single platform.