MicroPlex®
Microspheres
Non-magnetic microspheres that offer 100-plex capability and can be coupled to proteins or nucleic acids
About
MicroPlex® Microspheres are carboxylated polystyrene microparticles (“beads”) that have been color-coded into 100 spectrally distinct sets, or “regions.”
Each of these bead regions can be quickly distinguished by an xMAP® instrument, which allows for the interrogation of up to 100 different analytes simultaneously from a single sample.
MicroPlex® Microspheres are available at a concentration of 12.5 million beads/mL and can be ordered in 1 mL, 4 mL, and 16 mL vial sizes. MicroPlex® Microspheres are also offered in a variety of custom volumes. Please see the MicroPlex® Custom Volume Ordering Guidelines or contact Luminex to inquire about custom volume options.
All microspheres are general-use components for further manufacture of xMAP® bioassays.
IMPORTANT: MicroPlex microspheres are NOT compatible with the MAGPIX® System.
Features
- Surface carboxyl groups
- 100 Regions available
- Compatible with Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX®
- Multiple vial sizes available
- Available at 12.5 million beads/mL concentration
Benefits
- Proven reliability
- Suitable for both protein and nucleic acid applications
- Convenient vial sizes for all scales of work
To be used on
Instruments designed to accelerate reliable results while simplifying complexity.
Ordering info
MicroPlex® Microspheres regions 1–100, 1 mL, 4 mL, and 16 mL volumes ship within three business days of order receipt. However, back-ordered items may have longer than normal lead times.
MicroPlex® Microspheres have a maximum shelf life of five years from the date of manufacture, and all MicroPlex® Microspheres are guaranteed to have a minimum remaining shelf life of six months from the date they ship. Unfortunately, due to fluctuations in demand, it is not possible to guarantee a longer minimum shelf life for this product. Please refer to our Reagent Shipping Policy for more information.
Compatible with Luminex® 200TM, FLEXMAP 3D® and xMAP INTELLIFLEX®
Reg. |
Part number |
Reg. |
Part number |
Reg. |
Part number |
Reg. |
Part number |
---|---|---|---|---|---|---|---|
1 | LC10001-YY | 26 | LC10026-YY | 51 | LC10051-YY | 76 | LC10076-YY |
2 | LC10002-YY | 27 | LC10027-YY | 52 | LC10052-YY | 77 | LC10077-YY |
3 | LC10003-YY | 28 | LC10028-YY | 53 | LC10053-YY | 78 | LC10078-YY |
4 | LC10004-YY | 29 | LC10029-YY | 54 | LC10054-YY | 79 | LC10079-YY |
5 | LC10005-YY | 30 | LC10030-YY | 55 | LC10055-YY | 80 | LC10080-YY |
6 | LC10006-YY | 31 | LC10031-YY | 56 | LC10056-YY | 81 | LC10081-YY |
7 | LC10007-YY | 32 | LC10032-YY | 57 | LC10057-YY | 82 | LC10082-YY |
8 | LC10008-YY | 33 | LC10033-YY | 58 | LC10058-YY | 83 | LC10083-YY |
9 | LC10009-YY | 34 | LC10034-YY | 59 | LC10059-YY | 84 | LC10084-YY |
10 | LC10010-YY | 35 | LC10035-YY | 60 | LC10060-YY | 85 | LC10085-YY |
11 | LC10011-YY | 36 | LC10036-YY | 61 | LC10061-YY | 86 | LC10086-YY |
12 | LC10012-YY | 37 | LC10037-YY | 62 | LC10062-YY | 87 | LC10087-YY |
13 | LC10013-YY | 38 | LC10038-YY | 63 | LC10063-YY | 88 | LC10088-YY |
14 | LC10014-YY | 39 | LC10039-YY | 64 | LC10064-YY | 89 | LC10089-YY |
15 | LC10015-YY | 40 | LC10040-YY | 65 | LC10065-YY | 90 | LC10090-YY |
16 | LC10016-YY | 41 | LC10041-YY | 66 | LC10066-YY | 91 | LC10091-YY |
17 | LC10017-YY | 42 | LC10042-YY | 67 | LC10067-YY | 92 | LC10092-YY |
18 | LC10018-YY | 43 | LC10043-YY | 68 | LC10068-YY | 93 | LC10093-YY |
19 | LC10019-YY | 44 | LC10044-YY | 69 | LC10069-YY | 94 | LC10094-YY |
20 | LC10020-YY | 45 | LC10045-YY | 70 | LC10070-YY | 95 | LC10095-YY |
21 | LC10021-YY | 46 | LC10046-YY | 71 | LC10071-YY | 96 | LC10096-YY |
22 | LC10022-YY | 47 | LC10047-YY | 72 | LC10072-YY | 97 | LC10097-YY |
23 | LC10023-YY | 48 | LC10048-YY | 73 | LC10073-YY | 98 | LC10098-YY |
24 | LC10024-YY | 49 | LC10049-YY | 74 | LC10074-YY | 99 | LC10099-YY |
25 | LC10025-YY | 50 | LC10050-YY | 75 | LC10075-YY | 100 | LC10100-YY |
[-YY] = [-01] for 1 mL;
[-04] for 4 mL; or
[-16] for 16 mL
Please contact Luminex to inquire about custom vial sizes.
Region |
Instrument Compatibility |
Part number |
---|---|---|
1 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10001-YY |
2 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10002-YY |
3 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10003-YY |
4 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10004-YY |
5 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10005-YY |
6 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10006-YY |
7 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10007-YY |
8 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10008-YY |
9 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10009-YY |
10 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10010-YY |
11 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10011-YY |
12 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10012-YY |
13 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10013-YY |
14 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10014-YY |
15 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10015-YY |
16 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10016-YY |
17 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10017-YY |
18 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10018-YY |
19 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10019-YY |
20 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10020-YY |
21 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10021-YY |
22 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10022-YY |
23 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10023-YY |
24 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10024-YY |
26 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10026-YY |
27 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10027-YY |
28 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10028-YY |
29 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10029-YY |
30 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10030-YY |
31 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10031-YY |
32 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10032-YY |
33 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10033-YY |
34 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10034-YY |
35 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10035-YY |
36 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10036-YY |
37 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10037-YY |
38 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10038-YY |
39 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10039-YY |
40 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10040-YY |
41 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10041-YY |
42 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10042-YY |
43 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10043-YY |
44 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10044-YY |
45 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10045-YY |
46 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10046-YY |
47 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10047-YY |
48 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10048-YY |
49 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10049-YY |
50 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10050-YY |
51 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10051-YY |
52 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10052-YY |
53 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10053-YY |
54 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10054-YY |
55 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10055-YY |
56 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10056-YY |
57 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10057-YY |
58 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10058-YY |
59 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10059-YY |
60 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10060-YY |
61 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10061-YY |
62 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10062-YY |
63 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10063-YY |
64 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10064-YY |
65 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10065-YY |
66 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10066-YY |
67 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10067-YY |
68 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10068-YY |
69 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10069-YY |
70 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10070-YY |
71 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10071-YY |
72 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10072-YY |
73 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10073-YY |
74 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10074-YY |
75 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10075-YY |
76 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10076-YY |
77 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10077-YY |
78 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10078-YY |
79 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10079-YY |
80 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10080-YY |
81 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10081-YY |
82 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10082-YY |
83 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10083-YY |
84 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10084-YY |
85 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10085-YY |
86 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10086-YY |
87 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10087-YY |
88 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10088-YY |
89 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10089-YY |
90 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10090-YY |
91 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10091-YY |
92 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10092-YY |
93 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10093-YY |
94 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10094-YY |
95 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10095-YY |
96 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10096-YY |
97 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10097-YY |
98 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10098-YY |
99 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10099-YY |
100 | Luminex® 200™, FLEXMAP 3D®, and xMAP INTELLIFLEX® | LC10100-YY |
Resources
Blog
Discover morexMAP Insights magazine
Discover morexMAP Resource Round-Up
Discover moreResearch publications
Discover moreDocument repository
Product documentationWhite papers
Discover morexMAP® Kit Finder
Discover morePartners
Discover moreFind out more about all the xMAP® Microspheres
Delivering the versatility to perform a wide range of protein and nucleic acid-based multiplex assays—on a single platform.